1. About the filter
The RO-400-6 direct flow reverse osmosis system is designed to produce the highest quality drinking water by reverse osmosis technology (for more information on how reverse osmosis works, see. here).
2. Usage
This water purification systems can be used in apartments, cottages, private houses, etc. The quality of the water entering the reverse osmosis system must meet the minimum water quality requirements (see below)
3. Equipment set-up
The direct flow reverse osmosis system RO-400-6 uses:
First stage
5 Microns mechanical cleaning cartridge filter FCPS5. The function of this filter is to trap mechanical particles (sand, gravel, dirt, rust, etc.) that are larger than 5 microns.
Second stage
Carbon cartridge filter FCCBL. The purpose of this filtration stage is to clear chlorine, organic compounds and microorganisms from the water.
Third stage
1 Micron mechanical cleaning cartridge filter FCPS1. The function of this filter is to trap mechanical particles (sand, gravel, dirt, rust, etc.) that are smaller than 5 microns but larger than 1micron.
Fourth stage
Membrane. This is the main stage of a filtration in any reverse osmosis system. The key difference of this reverse osmosis system is the high performance membrane which capacity is up to 1,05 l/min. The model name is 400GPD.
Fifth stage
Cartridge filter element of activated carbon AICRO. It is installed between the membrane and the mineral granules filter element.
Sixth stage
Cartridge mineral granule filter element AIMRO. It is installed between the activated carbon granule filter element and the water tap to precisely complete the treatment of drinking water by enriching it with minerals.
4. Installation of the filter.
Installation is carried out by a qualified technician or on your own in accordance with the requirements of the "INSTRUCTIONS FOR USE" supplied with the equipment.
5. Terms of use:
Technical characteristics | |
Operating pressure range (bar) |
1.0-8.0 |
Operating temperature range (ºC) |
2-38 |
Minimum water quality requirements |
|
PH range |
3,0-11,0 |
Maximum salinity mg/ltr. |
2000 |
Turbidity (by Formazin) |
<0,1 |
Hardness mg. CaCO3
Mg-ekv/l. |
<650 mg/l. <13,0 |
Iron (Fe), mg/ltr. |
<0,3 |
Manganese (Mn), mg/l. |
<0,1 |
Hydrogen sulphide (H2S) mg/l. |
<0,03 |
Chlorine (CL2), mg/l. |
<0,5 |
Level of water purification due to membrane filtration |
|
Contamination type |
Level of purification (%) |
Mechanical impurities/ turbidity |
>99 |
Inorganic substances |
|
Natris |
90-95 |
Calcium |
93-98 |
Magnesium |
93-98 |
Iron |
93-98 |
Manganese |
93-98 |
Copper |
93-98 |
Nikelis |
93-98 |
Zinc |
93-98 |
Lead |
93-98 |
Chlorides |
90-95 |
Nitrates |
85-90 |
Phosphates |
93-98 |
Sulphates |
93-98 |
Cyanides |
90-95 |
Organic substances |
|
Organic molecules weighing more than > 200
|
>99 |
Organic molecules weighing less than > 200 |
Iki 99 |
Change intervals for filter elements |
|
Name of the filter element |
Change intervals |
Cartridge filter FCPS5 |
6 months |
Cartridge filter FCCBL |
6 months |
Cartridge filter FCPS1 |
6 months |
Cartridge carbon element Aimro |
12 months |
Cartridge mineralisation element Aimro |
12 months |
400GPD membrane |
4-8 years |
Reviews
There are no reviews yet.